Avid Technology MOS Gateway Specifications Page 113

  • Download
  • Add to my manuals
  • Print
  • Page
    / 152
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 112
Errors
113
Action: Open the MOS Gateway configuration file. Edit the
<out_lower> value in the <tcpPorts> group to insert a port number.
If there is no <out_lower> line, put one in the file. Stop and restart the
Router.
Error: MOS Out Upper port(RO) did not exist in config file.
Location: Event Log or Log file Source: MOS Gateway Router
Category: Startup
Action: Open the MOS Gateway configuration file. Edit the
<out_upper> value in the <tcpPorts> group to insert a port number.
If there is no <out_upper> line, put one in the file. Stop and restart the
Router.
Warning: roChannel was not found in the RoInfo data(roInfoData)
Location: Log file Source: MOS Gateway Router
Category: Miscellaneous
Action: This is a warning only. There is a problem with the iNEWS Server
software. Call Avid Broadcast customer support with the roInfoData for
assistance.
Warning: roInfo data(roInfoData) could not be loading into an XMLDOM
Location: Log file Source: MOS Gateway Router
Category: Miscellaneous
Page view 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 151 152

Comments to this Manuals

No comments