Chapter 4: Configuring and Installing I/O in Stage 48 11
Chapter 4: Configuring and Installing I/O in Stage 48
This section shows how to configure remote I/O, and how to
install compatible VENUE Stage I/O cards in Stage 48. The fol-
lowing Stage I/O cards are compatible with Stage 48.
AI16 Analog Input card
AO16 Analog Output card
XO16 Analog/Digital Output card
AT16 A-Net Output card
Configuring Remote I/O
How you configure the I/O in a Stage 48 depends on the con-
figuration of your current system.
Adding a Second Stage 48 to an
SC48 Remote System
You can expand the Stage I/O capacity of your SC48 Remote
system by adding a second Stage 48 and installing compatible
Stage I/O cards in it. SC48 Remote systems support up to the
maximum Stage I/O capacity of SC48–48 input channels and
32 output channels of combined local and remote Stage I/O.
Converting a Standard SC48 to an
SC48 Remote
If you have a standard SC48 console, it can be converted to an
SC48 Remote system. Converting your SC48 lets you connect
your SC48 to up to two Stage 48 units. In order to convert your
SC48, the top two AI16 input cards must be removed from
your console. These cards can then be installed in Stage 48.
You can choose to also relocate any other compatible Stage I/O
cards from SC48 to up to two Stage 48 units.
Example Configurations
The example configurations described in this section are
based on an SC48 with the following local Stage I/O:
Three AI16 Input cards (installed in SC48 slots A, B,
and C)
Two AO16 output cards (installed in SC48 slots D and E)
This SC48 could be reconfigured as an SC48 Remote system in
the following ways:
Relocate all SC48 Stage I/O to two Stage 48 units. Install
all three input cards in one Stage 48 and both output
cards in a second Stage 48. Remaining SC48 local I/O con-
sists of FOH inputs and outputs.
Relocate the first two AI16 input cards (corresponding to
Stage input channels 1–32) and the AO16 output card lo-
cated in Slot E (corresponding to Stage output channels
17–32) to a single Stage 48. Because of installation re-
quirements, the remaining local AI16 input card is lo-
cated in slot C of SC48, corresponding to Stage input
channels 33–48. The remaining local AO16 output card is
located in slot D of SC48, corresponding to Stage output
channels 1–16.
Relocate all three AI16 input cards to a single Stage 48,
and leave both output cards in SC48. All Stage inputs for
the system are located remotely in a single Stage 48, and
all Stage outputs are located locally in SC48.
The VENUE IO16 Option card cannot be installed Stage 48.
Converting an SC48 to an SC48 Remote system can only be
done by Avid-authorized service personnel. However, own-
ers are authorized to remove Stage I/O cards from SC48 and
install them into Stage 48.
These are only example configurations. Other configura-
tions are possible. The only requirement is that the top two
AI16 output cards must be removed when converting an
SC48 to an SC48 Remote system.